Skip to content

Sharp error cause 34 0000



 

Sharp error cause 34 0000. Code: F2-41. The factory default setting is one attempt at 3-minute intervals. Code: F2-42. . 2 which may cause issues with your Sharp MFP scanning to email. LSU harness, connector trouble LSU trouble LSU harness, connector trouble LSU trouble Remedy: Use SIM61-1 to check the operation of the LSU. Additional Functions: Press the Additional Functions (*) button once again. OPC drum cleaning trouble. Two and Eight Buttons: Press the 2 and 8 buttons at the same time once. The toner supply time exceeds 3 times as much as the specified time. - Create a share on another 2012R2 server and able to scan to folder to it. Jun 29, 2016 · When I run my app which is converting a Excel file, I get: Error: Retrieving the COM class factory for component with CLSID {00024500-0000-0000-C000-000000000046} failed due to the following error: 8000401a The server process could not be started because the configured identity is incorrect. Description: LSU laser detection error; Causes: Optical axis shift. If [Print at Error] is selected when Inbound Routing is enabled, received faxes will only be printed when an error occurs. Remedy: Use SIM49-1 to perform the firmware version-up procedure again. com recipient mbox2@domain. - Create a second shared folder on server. Trouble content Punch motor operation abnormality. Harness and connector trouble between the LD/BD PWB and the LSU control PWB. Sending to M365 requires TLS 1. SCU PWB trouble. 2 now. Causes: Toner density sensor output abnormality (Sample level 34 or less, or 221 or above) Harness and connector connection trouble. If you are unable to solve a problem using the solutions in this manual, press the [POWER] button and then turn the main power switch to the " "position. Replace the MFP PWB. 5. overvoltage, finisher control PWB trouble or punch control PWB trouble. Causes: Motor lock, control PWB trouble, disconnection of harness or connector, HP sensor breakdown. Causes: The firmware update is failed because of turning OFF the power during the firmware update operation, etc. “Disabling of full color” is selected for User Authority. Replace the ROM. Bypass tray , tray 5, tray 6: Load the paper with the print side facing down *. --> Remove and insert the 1ST Code: C1-10. Description: Fusing section low temperature trouble (TH_US) Causes: The fusing temperature does not reach the specified level within the specified time from turning ON the power relay. 2) Check from the Web Page to confirm that the Primary/Secondary E-mail server address or the FTP server/ Desktop PC address as the destination is properly set. Press Network Settings. Either it’s torn or the little white patch at the end of the film is dirty. PrintCopy . Page 28 E-MANUAL UPDATE SHARP 4. Description: Toner density sensor trouble (K) Causes: Toner density sensor output abnormality. account-job-id. The fan operation signal is not detected. After the main power indicator changes from flashing green to the lit up state, press the [POWER] button. If you are unable to solve a problem using the solutions in this manual, see TURNING ON THE POWER to restart the machine. Developing unit trouble. Check connection of the connector and the harness. info service 2001 - 2024. High voltage TC PWB trouble. 1 day ago · Descale the washing machine - this is how it works ; Washing machine: service life and guarantee at a glance ; Cleaning the washing machine - this is how it works Case 2 Cause Network setup trouble Check and remedy 1) Check that the connected network supports TCP/IP protocol. May 1, 2023 · Solution: Inspect and replace the faulty component. Lors de la mise hors tension , éteignez d’abord l’interrupteur marche / arrêt sur le panneau de commande. The secondary transfer unit is not installed properly. ROM trouble. Code: L4-34. Replace the MFPC PWB. 3. Code: A0-04; Description: Scanner expansion PWB (ACU) (ACRE) ROM error Description: SCU PWB ROM error; Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. - Verify Security and Share permissions. Remedy: * Change the setting to B/W print. 6. Computer Name. 24 volt detection circuit Trouble at FAX PWB. i called sharp and they told me that the printers needed a firmware update this appears to have fixed the issue. Using a PC, copy the E-Manual Update directory onto the root of a USB memory device (as shown). Causes: DC power supply trouble at the main machine. Replace the LSU. Dec 9, 2020 · Unable to print to Sharp MX-M283N with error cause 040DHelpful? Please support me on Patreon: https://www. SCN MFP PWB trouble; Remedy: SIM49-1 to execute the firmware update Replace SCN MFP PWB; Code: A0-06; Description: FAX ROM error; Causes: The content of FAX ROM error Jan 4, 2023 · Hello , I have the same message coming but I, did nt get to add not even one lamp on smart things Did you find any solution till now? PASS# NG. Causes: Laser optical axis misalignment Reduced laser power, lighting error, laser diode trouble. Caution: When copying the E-Manual firmware/directories onto the USB drive, do not change the folder hierarchy or files. Remedy: 1. Causes: Open circuit of the 1st transfer out put. SCN-MFP PWB trouble (Fuse break trouble). Use SIM8-6 to the check the out put of [THV]. /. Causes: Toner motor section connector harness trouble Toner motor and toner density sensor trouble. F2. Connection trouble of the connector and the harness. Code: L4-35. -> Replace the transfer unit. • A network trouble (CE-XX) occurs. Code: A0-06; Description: FAX ROM error; Causes: The content of FAX ROM is abnormal Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. MFP PWB trouble Harness and connector connection trouble. Job Mode. Heater lamp trouble. Wait at least 10 seconds and then turn the main power switch to the " "position. Trouble. Description: PCU ROM error; Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. ). She is good at data recovery and disk & partition management, which includes copying partitions, formatting partitions, etc. MFPC PWB trouble Harness and connector connection trouble. Remedy: Check connection of the connectors and the harness. The drum marking sensor is dirty. Description: FAX power supply trouble. Replace the LSU cooling fan. If the leakage noise or the flickering on the screen of the panel is detected; 1) Abnormality of the transfer unit. Check thermistor. Causes: Connector connection trouble Toner cartridge installation trouble Sensor breakdown; Remedy: Connect the connector again. The job mode type, such as copy or print is recorded. Then switch off the machine and turn the power back ON at the power socket and the code should reset. => "Setting mode (administrator)" → [Application Settings] → [Inbound Routing Settings] → [Administration Settings] → [Inbound Routing Settings] Mar 16, 2023 · The error codes include: 03-0000, 02-0023, 46-0034, 06-0000, 05-0002, 16-0030, 34-0000, probably a few others, and Receive Impossible ( 01-0002 & 05-0000)while sending or receiving. Scroll to the bottom. Telnet needs to be turned on/activated (program and features, turn on windows features). Code: A0-04; Description: Scanner expansion PWB (ACU) (ACRE) ROM error Things I have done in trubleshooting: - Disable Windows Firewall. Click the “OK” button at the bottom of the screen. 2 implementation, working as of 9-19-2018. Error: 'No dial tone detected: 45' when trying to send a via an analog fax modem See more Error: 'Call Failed 46' when receiving faxes ( ECM ) Description: SCU PWB ROM error; Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. If not , port 4687 is being blocked by the firewall. print print the page currently displayed ; print the category currently displayed GENERAL PROBLEMS. Scanner unit trouble. Sharp MX3501N states "selected server could not be found Description: Toner density sensor trouble. RX POLL FAIL. The primary transfer unit is not installed properly. • Authentication of the POP server is failed when POP before SMTP is enabled. Scanner home position sensor trouble. patreon. SCN MFP PWB trouble; Remedy: SIM49-1 to execute the firmware update Replace SCN MFP PWB; Code: A0-06; Description: FAX ROM error; Causes: The content of FAX ROM error Description: MFP boot error; Causes: ASIC trouble Memory trouble; Remedy: Extract and insert eMMC PWB Replace eMMC PWB Replace SCN MFP PWB; Code: A0-20; Description: MFP firmware and EEPROM data inconsistent error; Causes: Inconsistency between MFP firmware version and EEPROM data version; Remedy: SIM49-1 to execute the firmware update Apr 11, 2022 · Code Description CommentAO-01PCU PWB ROM errorSimulation Code - 16AO-02SCU PWB ROM errorSimulation Code - 16AO-10Color profile errorSimulation Code - 16AO-11Firmware Description: SCU PWB ROM error; Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. It is recorded regardless of whether or not the OSA is present. Unsolved problems for sharp printer error code 80 0000 question. a. Remedy: Check the 24 volt supply circuit between the machine and the FAX PWB. Code: A0-02; Description: SCU PWB ROM error Apr 15, 2021 · Make sure the DNS settings on the network card are legit. Remedy: Replace the toner density sensor. v Sub code 31: Process control problem, drum or sensor not working properly. 4. At the MFP control panel press System Settings and login as Admin (or Key Operator) b. com. e. The connection was broken because the polling passcode was not correct. Code: H4-02. Solution: Check the power supply and control board for issues and replace if needed. Remedy: 1) Check & Remedy Use SIM8-6 to check the out put of [1TC-K/C/M/Y]. If you can, lock the speed on that switch port to 100 MBPS and reboot the printer. Same result. Touch the “ERR” button to highlight it. Touch the “CLEAR” button on the screen. Harness trouble between the FAN PWB and SCNMFP PWB. Reduced laser power, lighting error, laser diode trouble. I have troubleshot this for the past 5 days to no avail and EE is my last hope before having to implement something else instead of resolving the problem. SCN MFP PWB trouble; Remedy: SIM49-1 to execute the firmware update Replace SCN MFP PWB; Code: A0-06; Description: FAX ROM error; Causes: The content of FAX ROM error Sharp Photocopieur » Codes erreur SHARP. Remedy: Use SIM49-1 to execute update of the firmware. For a Gemini Plus / Aries it's: NG80 XXXX *1. d. Parfois, ce code peut être effacé en éteignant la machine , puis en la redémarrant . Code: L1-00. Description: Color profile error; Causes: The content of the color profile is abnormal Combination inconsistency between MFP firmware and color profile; Remedy: SIM49-1 to execute the firmware version up Replace SCN MFP PWB; Code: A0-15; Description: Stored DSK data conflict; Causes: Inconsistency of ASIC MAIN firmware version Jun 19, 2023 · Shark NV360 Navigator Lift-Away Deluxe Upright Vacuum with Large Dust Cup Capacity, HEPA Filter, Swivel Steering, Upholstery Tool & Crevice Tool, Blue The job ID used in the Sharp OSA is recorded. Though the sensor gain is changed, the output is not fixed to a certain level. Description: SCU PWB ROM error; Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. Code: A0-02; Description: SCU ROM error In "Setting mode", select [System Settings] → [Image Send Settings] → [Fax Settings] → [Send Settings] → [Recall in Case of Communication Error]. Send and receive messages from your doctor's office. Check connection of the connectors and the harness. Remedy: Use SIM3-3 to check the operation of the saddle rear edge hold motor. Remedy: Case 1 Cause Toner motor section connector harness Description: SCU PWB ROM error; Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. 2 in SMTP sending, not just in the web interface of v Sub code 50: Non-support trouble in option connection. *. Causes: Scanner feed is not completed within the specified time. PCU PWB trouble Thermostat trouble. trace_login (on the cli: 'options cifs. NO F-CODE POLL. Remedy: Use SIM49-1 to perform the version-up procedure again. Make sure the printer’s firmware supports TLS 1. SMON message: You don’t have the authority to use this function. User Name. Description: Toner supply abnormality (CYAN) Toner end with the remaining quantity of 50% or more. Check connection of the sensor connector and the harness. Replace the developing unit with a normal one. Description: PCU PWB ROM error; Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. v Sub code 02: Toner motor disconnected. Install the developing unit again. PCU PWB trouble; Remedy: Use SIM49-1 to perform the firmware version-up procedure again. Code: A0-04; Description: Scanner expansion PWB (ACU) (ACRE) ROM error Code: F2-37. protection. Replace the SCU PWB. Code: A0-01. c. Check the fuser lamp. Code: C1-10. The user name when the user authentication function is used is recorded. - Verify SMB 1, 2, and 3 are enabled. Connector, harness connection trouble. - Cables replaced. Error Code: Service Mode, Troubleshooting: Parts Catalog: Email: Password: Sign In : New Register: Forgot Password? Description: SCU PWB ROM error; Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. com/roelvandepaarWith thanks & praise to G PrintCopy . Description: Toner density sensor trouble (C) Causes: Toner density sensor output abnormality. Make sure that the print side of paper is facing in the correct direction. Breakage of the high voltage harness. Login Name Touch the “FUNCTION” button at the top of the screen. Error Code: Service Mode, Troubleshooting: Parts Catalog: Email: Password: Sign In : New Register: Forgot Password? Code: F6-02. Cause: Locked or obstructed scanner, or faulty motor. Replace the PCU PWB. Description: SCU ROM error; Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. Code: A0-04; Description: Scanner expansion PWB (ACU) (ACRE) ROM error Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. Description: 1st transfer High-voltage output trouble. Lorsque la machine affiche un code d’erreur, il y a un problème fonctionnel avec la machine. Here are the steps to combat this issue: Description: PCU PWB ROM error; Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. The job ID used in the OSA is recorded. Remedy: Use SIM61-1 to check the operation of the LSU. Check the fuser film. Code: F2-65. NO RX POLL. Touch the Copier button on the screen. -> Remove and insert the transfer unit. Sensor connector and harness connection trouble. Replace the DC controller PCB. Code: F2-40. Code: A0-02; Description: SCU PWB ROM error E-MANUAL UPDATE SHARP MX-2310U Only 1. Get free help, tips & support from top experts on sharp printer error code 80 0000 related issues. v Sub code 00: Toner sensor. In "Setting mode", select [System Settings] → [Image Send Settings] → [Fax Settings] → [Send Settings] → [Recall in Case of Communication Error]. - Disable AV. Check the connector of the fixing film unit. 07-28-2016 #3. Causes: Scanner return is not completed within the specified time. PCU PWB trouble Connection trouble of the connector and the harness. Sep 22, 2010 · Most of our Multi Function Printers (about 8) have suddenly stopped scanning to our network share (on a Windows Server 2003 server). Code: L3-00. Cause: Motor lock, motor RPM abnormality, motor. Description: MFP boot error; Causes: ASIC trouble Memory trouble; Remedy: Extract and insert eMMC PWB Replace eMMC PWB Replace SCN MFP PWB; Code: A0-20; Description: MFP firmware and EEPROM data inconsistent error; Causes: Inconsistency between MFP firmware version and EEPROM data version; Remedy: SIM49-1 to execute the firmware update Dec 15, 2015 · Error: 435. Causes: The PTC unit is not installed properly. I have tried switching from a hostname in the UNC path to an IP address in case it was something to do with DNS. L1-00: Scanner Feed System Problem. Hi, We seem to be having the same scan to email issue many have had I have tried adding <> to the email address and adding the address in image send settings but to no avail Description: TC output error; Causes: Open/Short circuit of the transfer out put. 2 implementation, seems to be working. *When the paper type is "Pre-Printed" or "Letter Head", load the paper in the opposite way. Select Copier: The System Management screen will open. Error Code: Service Mode, Troubleshooting: Parts Catalog: Email: Password: Sign In : New Register: Forgot Password? F1-34. Check and remedy: Use SIM3-3 to check the operation of the punch motor (FPNW). Some of the possible causes. Cause: Faulty power supply or control board. Get answers to your medical questions from the comfort of your own home. Examples of messages that are printed in the result column Message Description; OK: The transaction was completed normally. Follow the steps below: Check the fuser film: You have to remove the Fuser unit (FG6-6040-000) from the machine and manually rotate the gear. Replace the fusing cooling fan. PCU PWB trouble. trace_login on' ) and watch the messages file when you try the operation. Causes: LSU cooling fan trouble. v Sub code 32: Drum mark sensor problem, drum or sensor. Description: Toner density sensor trouble (M) Causes: Toner density sensor output abnormality. This procedure is for Sharp multi-function devices. mail. Aug 29, 2018 · Timeout error” when trying to scan using an Address Book entry. In the IPv4 address enter the IP address of the computer hosting the shared folder. Disconnection of the high voltage PWB connector. digital multifunctional system mx-m365n/mx-m465n/mx-m565n user's manual. Thermistor trouble. If the leakage noise or the flickering on the screen of the panel is detected; (1) Abnormality of 1ST transfer unit. Description: Main charger trouble (BK) Causes: The main charger unit (BK, C, M, Y) is not installed properly. open command line type; telnet (ip address of pc) 4687 (default port Network scanner tool uses) you should get a response of 220 Sharp - Network Scanner Tool ftp server. Cause: * “Disabling of Colour Mode” is selected. Remedy: Use SIM6-2 to check that the fan is actually rotating. SCN-MFP PWB trouble. Mar 22, 2011 · Hi, Try enabling the option cifs. Sep 26, 2023 · Position: Columnist Charlotte is a columnist who loves to help others solve errors in computer use. Before starting process control, the drum marking area surface is read by the sensor to make the sensor gain adjustment so that the output is fixed to a certain level. Causes: Fusing cooling fan trouble. The machine that was polled does not have a polling function. Code: A0-04; Description: Scanner expansion PWB (ACU) (ACRE) ROM error Some notes if you're emailing in the same o365 domain: You can email from/through a shared mailbox, don't need a license smtp host is like: domain-com. * 5. Check the PWB and connection of the harness in the LSU. It looks like you should have <> brackets on your reply to address. Description: SCN ROM error; Causes: The firmware update is not completed properly by interruption of the power during the update operation. SCN MFP PWB trouble; Remedy: SIM49-1 to execute the firmware update Replace SCN MFP PWB; Code: A0-06; Description: FAX ROM error; Causes: The content of FAX ROM error Jan 26, 2022 · Office365 Scan to Email not working - Sharp copier solution or fix for Office 365 SMTP TLS 1. Do not worry if you get this error, in some rare cases, you can solve it by a very simple process. If there is a display name, it can't be fake or different from the o365 domain name. Replace the control PWB, the motor, and the sensor part. Use SIM6-2 to check the rotating operation of the fan. v Sub code 80: Finisher power problem. Code: C4-00. If pinging does not generate responses then the connection must be fixed first. Trays 1 to 4: Load the paper with the print side facing up *. Code: A0-11; Description: Firmware version inconsistency (MFP - PCU) Jun 5, 2013 · Re: NG800000 when scanning to email. com port 25 no auth, tls or SSL sender: mbox@domain. We have a quick and simple solution that as of today, 9-19-2018 after the TLS 1. Description: Fusing cooling fan trouble. Check the username and password. The machine will process for 2 minutes. Replace the finisher punch unit (Replace the punch control PWB. This does not happen with every fax, and faxes to the same number work 30 min later. Check connection from the control PWB to the motor and the sensor. Code: A0-04; Description: Scanner expansion PWB (ACU) (ACRE) ROM error Jan 11, 2016 · This could be an auto negotiation failure, especially if it is a Gigabit switch. SCN MFP PWB trouble; Remedy: SIM49-1 to execute the firmware update Replace SCN MFP PWB; Code: A0-06; Description: FAX ROM error; Causes: The content of FAX ROM error e000000-0000Code resetting: Additional Functions: Press the Additional Functions (*) button once. NIC connect failure (network abnormality) • Check for disconnection of cables. Scanner motor trouble. outlook. The other machine refused the polling operation, or your machine broke the connection when polled because no data was in memory. The name of the computer that sent a print job is recorded. Remedy: Use SIM1-1 to check the scan operation. Cancel “Disabling of full color” by the Administrator. Replace the scanner unit. H4-00: Fusing Unit Heating Problem. Description: MFP boot error; Causes: ASIC trouble Memory trouble; Remedy: Extract and insert eMMC PWB Replace eMMC PWB Replace SCN MFP PWB; Code: A0-20; Description: MFP firmware and EEPROM data inconsistent error; Causes: Inconsistency between MFP firmware version and EEPROM data version; Remedy: SIM49-1 to execute the firmware update Sep 19, 2018 · Recently Microsoft Office 365 SMTP implemented the mandatory use of TLS 1. /Trouble. Replace the developing unit. OK REPORT: A receive report was requested for a transmission, the transmission was completed normally, and the receive report was received from the destination. Configuration is the same as far as I can see. There is an abnormality in the main charger unit (BK, C, M, Y). Code: C4-20. • The port is set to DISABLE. ty wr qh re rn yp io dz lm qt